It is not always necessary to run a continuous wire from the ground to each individual part in a bonding system.
Ground bond on panel door.
One of the most common defects i find related to remote distribution panels sub panels is ground wires and neutral wires bonded together.
The ground bar is bonded internally when an external bond to earth is installed as described at the link for electrical grounding below.
Second the main electrical panel must be grounded to a grounding electrode such as a ground rod or rods driven into the earth near the foundation of your house.
Bonding has to be done by connecting of all the metal parts that are not supposed to be carrying current during normal operations to bringing them to the same electrical potential.
This connector bonds the ground conductor to the backpanel.
This is especially true if the work has been done by homeowners or handy persons.
Grounding bonding 5 grounding and bonding grounding and bonding are important elements of a building s electrical wiring system.
In simple terms the only place we want to bond the grounds and neutrals together is in the service equipment.
Btw i would say that any connection would be a bonding jumper and its purpose would be to ground the door by establishing a solid connection between the 2 components.
Although the piping system is bonded to the ground through your main electrical service panel the panel grounding and the piping bonding are unrelated when it comes to function.
The bonding in panels are done two different ways.
Neutral bonding in panels.
Metal doors whether continuous hinge type or removeable hinge need a separate bonding jumper from the enclosure or backpanel to the door and are usually provided.
Sub panel the neutral wire is not bonded connected to the ground wire.
What s the difference between bonding and grounding.
The code defi nes grounding as the connecting to ground or to a conductive body that.
In certain conditions metal parts need only be connected to each other to form a complete bonding system.
These terms are similar confusing and often used interchangeably.
This sub feed cable will have 2 insulated power conductors 1 insulated neutral conductor and one.
Backpanels are installed with nuts or machine screws and star washers to ensure they are bonded to the metal enclosure.
Grounding a sub panel.
Typically panel doors will have a small bonding jumper that bonds the door to the metal backpan or grounding conductor.
Sub panels are grounded through the cable that provides the sub feed circuit power.
They each have different functions but they work together to make the building s electrical wiring safe.
Main panel the neutral wire is bonded connected to the ground wire.