Gap Between Roof Sheathing And Insulation

Unvented Roof For Cold Climate Metal Roofing Over Exterior Rigid Foam Greenbuildingadvisor Com Metal Roof Roof Insulation Rigid Roof Insulation

Unvented Roof For Cold Climate Metal Roofing Over Exterior Rigid Foam Greenbuildingadvisor Com Metal Roof Roof Insulation Rigid Roof Insulation

Unvented Attic Insulation Building America Solution Center Roof Insulation Roof Cladding Patio Roof

Unvented Attic Insulation Building America Solution Center Roof Insulation Roof Cladding Patio Roof

Image Result For Exterior Roof Insulation Roof Insulation Rigid Insulation Metal Roof

Image Result For Exterior Roof Insulation Roof Insulation Rigid Insulation Metal Roof

Air Sealing Sip Seams Roof Insulation Roof Construction Sip House

Air Sealing Sip Seams Roof Insulation Roof Construction Sip House

Metal Roof Section Detail Metal Roof Rigid Insulation Roof Sheathing

Metal Roof Section Detail Metal Roof Rigid Insulation Roof Sheathing

Vented Roof For Mixed Climate Cathedral Ceiling Asphalt Roofing Vinyl Lap Siding Over Ri Shingle Roof Details Roof Insulation Details Asphalt Roof Shingles

Vented Roof For Mixed Climate Cathedral Ceiling Asphalt Roofing Vinyl Lap Siding Over Ri Shingle Roof Details Roof Insulation Details Asphalt Roof Shingles

Vented Roof For Mixed Climate Cathedral Ceiling Asphalt Roofing Vinyl Lap Siding Over Ri Shingle Roof Details Roof Insulation Details Asphalt Roof Shingles

To maintain airflow leave a space of 38 to 50 mm 1 1 2 to 2 in between the top of the insulation and the underside of the roof sheathing.

Gap between roof sheathing and insulation.

The problem arises with moisture. In the winter humidity from the house s interior will get past the insulation and come in contact with the cold roof sheathing where it will condense into water. The gap between the roof sheathing and the insulation over a ceiling is varied between 1 and 3 inches. Or if you are perfect with your rainwater control such as when you use a fully adhered membrane think roof membrane standing up applied to a wall.

Use baffles between each rafter space to prevent it from being blocked see figure 5 11. An air space between the insulation and the bottom of the roof sheathing is desirable. The code calls for a minimum of 1 in. Batts should cover the top plate of the exterior wall but not block the venting.

The moisture is held in place by the insulation which allows for damage to the framing and other building components. Spacer type panel edge clips are available from some manufacturers. Of airspace between the top of the insulation and the back of the roof sheathing. For best performance the airspace in the vent chute should be a minimum of 2 in.

Several local and international building codes recommend a minimum of 1 inch gap between the sheathing and insulation. If there is a roof leak the insulation will be damaged by the water leaving you with less insulating value. Roof sheathing panel spacing hints. Unless you provide a small gap between the exterior face of the osb and the back surface of the foam sheathing to provide for some hygric redistribution.

There are no irc requirements for spacing wood sheathing that i am aware of. T he problem with the insulation against the sheathing expands. Unless you re bulk filling rafter bays between 2 10 or 2 8 rafters with closed cell spray foam this approach.

Rr 0108 Unvented Roof Systems Roofing Systems Roof Insulation Details Roof Insulation

Rr 0108 Unvented Roof Systems Roofing Systems Roof Insulation Details Roof Insulation

Insulating Walls With No Sheathing Wall Insulation Exterior Wall Insulation Rigid Foam Insulation

Insulating Walls With No Sheathing Wall Insulation Exterior Wall Insulation Rigid Foam Insulation

Unvented Roof Cavity Insulation Roof Underlayment

Unvented Roof Cavity Insulation Roof Underlayment

Attic View Roof Deck Rafters Lookouts Fascia And Plywood Soffit Fascia Home Maintenance Roof

Attic View Roof Deck Rafters Lookouts Fascia And Plywood Soffit Fascia Home Maintenance Roof